Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan

Product Details
Customization: Available
Material: Carbon Structural Steel
Usage: Smoke Exhaust
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (27)
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
  • Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
Find Similar Products
  • Overview
  • Product Features
  • Product Parameters
  • Application
  • Driven mode
  • Related products
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
5-10
Flow Direction
Centrifugal
Pressure
Medium Pressure
Certification
ISO, CE
Blade Material
Stainless Steel
Impeller Diameter
400-1000mm
Speed
≤2900rpm
Selling Units
Single Item
Customized Support
ODM OEM Obm
Electric Current Type
AC
Application
Industrial Blower
Power Source
Electric Blower
Rated Voltage
380V
Warranty
1year
Bearing Cooling
Air Cooling or Circulating Water Cooling
Impeller Support
Swsi, Dwdi, Overhung Type
Main Shaft
High-Strength Carbon Structural Steel
Transport Package
Steel Pallet Waterproof Cloth Package
Trademark
SIMO BLOWER
Origin
Henan, China
HS Code
4107960701
Production Capacity
300 Set/Sets Per Month Centrifugal Fan

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
150.000kg

Product Description

Coal-fired boiler system with backward centrifugal induced draft fan

Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan

The 5-10 series ventilator is a high efficiency and energy saving product developed by our company, which is used for ventilation and exhaust system of smelting, chemical, medicine and dust removal production lines.
In the coal-fired boiler system, the ventilation and induce draft systems of various boilers with evaporation capacity of 20 tons/hour to 800 tons/hour can be configured.

Product Features

1.It can output higher outlet pressure and provide more gas flow at the same time, low noise. Stable operation at higher media temperatures.
 2. The fan speed can be flexibly set by matching different belt pulley diameters to make the fan run at the highest efficiency point and reduce energy waste.
3. Motor slide guide can be provided for convenient belt tensioning to reduce energy loss caused by belt slack.
4. The bearing housing is reserved for the installation position of temperature and vibration sensors, which can facilitate the installation of fan operation monitoring device.
5. Use liquid lubricating oil. It is not necessary to open the bearing housing to replace and fill the lubricating oil. The bearing housing is provided with an observation window for easy observation of the quality and stock of the lubricating oil.
6. The bearing housing uses labyrinth mechanical seal, unique anti-leakage design inside, vent hole at the top, and sealing grease at the joint, completely eliminating the possibility of oil leakage in the bearing hosing.
7. After annealed treatment, the internal stress of the structure generated during welding can be completely eliminated to ensure that the impeller will not creepage and crack.
8. The impeller is subjected to a high standard of dynamic balancing adjusting to ensure stable operation of the fan.
9. After running test and vibration value detection, the operation is reliable

Product Parameters

The following datas are only part of performance of our product.
If you can't find the datas you need, pls send us your performance requirements
we will provide you customized design service.
Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
series model Rotation Speed
(r/min)
Total Pressure
(Pa)
Air Capacity
(m³/h)
Power
(kW)
5-10 4D 2900 1606~1232 3007~5152 3
4.5D 2880 2004~1538 4252~7284 5.5
5D 2900 2509~1925 5873~10062 7.5
5.4D 2900 2927~2246 7398~12675 11
6D 2500 2685~2060 8749~14989 15
8D 2000 3055~2344 16591~28424 30
9D 2000 3867~2967 23623~40471 45
10D 1600 3055~2344 25923~44413 45
Application
Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
Driven mode

Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan

Related products
 
 
Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
Our Advantages
Coal-Fired Boiler System with Backward Centrifugal Induced Draft FanCoal-Fired Boiler System with Backward Centrifugal Induced Draft FanCoal-Fired Boiler System with Backward Centrifugal Induced Draft FanCoal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
Packaging & Shipping
Coal-Fired Boiler System with Backward Centrifugal Induced Draft Fan
FAQ

Coal-Fired Boiler System with Backward Centrifugal Induced Draft FanContact us to get a quote

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier